APC BK500EI 500 VA 300 Watts (1) IEC 320 C13 (Surge Protection)
(3) IEC 320 C13 (Battery Backup)
(2) IEC Jumpers (Battery Backup) Outlets Back-UPS CS 500 USB/Serial
| Model | | Brand | APC | | Model | BK500EI | | Input | | Input Voltage Range | 196 - 280V | | Input Frequency | 50/60 Hz +/- 3 Hz (auto sensing) | | Output | | VA Rating | 500 VA | | Watts | 300 Watts | | Output Voltage | 230V | | Outlets | (1) IEC 320 C13 (Surge Protection) (3) IEC 320 C13 (Battery Backup) (2) IEC Jumpers (Battery Backup) | | Battery | | Battery Run Time | Typical Backup Time at Half Load: 13.9 minutes (150 Watts) Typical Backup Time at Full Load :2.4 minutes (300 Watts) | | Battery Recharge Time | 6 hour(s) | | Spec | | Interface Port | DB-9 RS-232,USB | | Approvals | C-tick,CE,EN 50091-1,EN 50091-2,GOST,VDE | | Surge Protection | | Data Line Protection | RJ-45 Modem/Fax protection (two wire single line) | | Surge Energy Rating | 300 Joules | | Physical Spec | | Weight | 13.90 lbs | | Dimensions | 6.50" x 3.60" x 11.20" | | Features | | Features | Battery-protected and surge-only outlets Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment. Dataline Surge Protection Provides protection of connected equipment from power surges on the data lines. Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances. Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals. Audible alarms Provides notification of changing utility power and UPS conditions. Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Battery replacement without tools Provides reduced risk of load disruption by allowing quick and easy battery replacement. LED status indicators Quickly understand UPS status with indicators. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced. Resettable circuit breakers Enables quick recovery from UPS overload events. Transformer-block spaced outlets Protect equipment with input transformer blocks without blocking access to other receptacles. User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR). |
|